Please
Note: We have discontinued our GE
Product Line of Ozone Generators (GE30 & GE60). The GE60/FMxx
has been replaced by the OL80W/FMxx which
is a more energy efficient product with better performance and
increased versatility (EXT
port).
Flow in Liters
per Minute (LPM) -> 1 LPM -> 1000 ml/min
(1000 ml/min)
Ozone Concentration in Gamma -> 1 gamma -> 1µg/ml -> 1
mg/l -> 1gr/m3
Temp:
21 C
Feed gas: Oxygen/Med.
Pressure: 100.1 kPa
Note: YY/5.5/120/714/BT/15C/12VDC |
Date:
Aug 22, 1999
Model: GE60/12VDC
Serial #: 990822.b
File: 990822DC.OUT |
Flow
in Liters Per Minute (LPM). |
Ozone
concentration in GAMMA (µg/ml) |
|
|
FLOW |
FLOW |
-------
OZONE CONCENTRATION REGULATOR SETTING ----------
|
LPM |
cc/min |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
|
|
|
1/32 |
31 |
22 |
29 |
38 |
46 |
53 |
59 |
68 |
77 |
84 |
90 |
|
1/16 |
62 |
10 |
13 |
19 |
24 |
29 |
34 |
44 |
53 |
63 |
73 |
|
1/8 |
125 |
7 |
9 |
13 |
16 |
20 |
24 |
32 |
39 |
50 |
60 |
|
1/4 |
250 |
4 |
5 |
7 |
9 |
12 |
14 |
19 |
23 |
30 |
36 |
|
1/2 |
500 |
3 |
4 |
5 |
5 |
6 |
7 |
10 |
12 |
16 |
19 |
|
3/4 |
750 |
2 |
3 |
4 |
4 |
5 |
5 |
7 |
9 |
11 |
12 |
|
1 |
1000 |
1 |
2 |
3 |
3 |
4 |
4 |
6 |
7 |
9 |
10 |
|
|
|
Test - concentration regulator setting #1, #2, #4, #6, #8 and #10
with oxygen flow from 1/32 LPM to 1 LPM (bold print).
Estimate - setting #3, #5, #7 and #9 (plain print)
Please
see out page on How to Read
the Ozone Test Report for
an explanation of the above report.
|